The fans shall be tested and rated according to AMCA Standard 210. They shall be certified by the Air Movement and Control Association (AMCA) and shall be licensed to bear the AMCA seal. Fans shall be model CI or NH as manufactured by KCH Services, Inc.
Provide factory-assembled and tested fan units consisting of housing, wheel, fan shaft, bearings, access door, corrosion resistant support structure, drive, motor, drain, and OSHA approved belt guard and shaft cover.
All fan parts in contact with the airstream shall be resistant to corrosion by chemicals in the air stream. Fan housings shall be PVC, Polypropylene, or FRP Material.
Wheels to be keyed to shafts. Steel wheels to be minimum Class II construction and coated with FRP. Solid FRP, Stainless Steel, or Hastelloy wheels can be offered as an alternative. Wheels to be statically and dynamically balanced after assembly and before shipment.
Provide heavy-duty grease lubricated, precision anti-friction ball or roller, self-aligning, pillow block type bearings selected for minimum average life (AFBMA L 50) of 100,000 hours.
Provide V-belt drive, selected for 1.5 services factor. Belts shall be provided in matched sets.
Fans to be arrangement 9 for motors of less than 40 H.P. and Arrangement 1 for motors 40 H.P. and above.
Provide slide rail motor base.
Provide totally enclosed fan cooled motors, 230/460 volt, 3 phase, 60 hertz. 1800 RPM or 3600 RPM.
Provide bolted access door in housing scroll. Provide stainless steel bolts with bolt surface inside housing capped and sealed.
Provide 1" - 1 1/2" dia. coupling drain connection at lowest point of housing.
Provide flanged or flexible type inlet and flanged outlet connections.